N2XH 3G4 mm2

Description

Description

Standards

  • Product
    IEC 60502-1

Application

N2XH cable is an installation/power cable widely used in applications requiring high levels of fire safety due to the significant number of human lives at stake, such as: 

  • Industrial and Commercial Electrical Installations
  • Electrical panels and control panels
  • Indoor applications with fire risk (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices etc.)
  • Installations in public places
  • Tunnels and underground infrastructures
  • Wiring for indoor power and lighting circuits in dry environments

Construction

  1. Conductor:Copper
  2. Insulation:XLPE
  3. Filler:LSZH
  4. Outer sheath:LSZH

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Circular stranded (RM)
With smaller neutral conductor
No
Insulation
XLPE (chemical)
Outer sheath
HFFR (Halogen Free Flame Retardant)
Halogen free
IEC 60754-1
Conductor flexibility
Stranded class 2
Core identification
Blue, brown, green / yellow
Sheath colour
Black
With Green/Yellow core
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
4 mm²
Neutral conductor section (when smaller)
- mm²
Nominal outer diameter
13.0 mm
Approximate weight
260 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Max. DC resistance of the conductor at 20°C
4.61 Ohm/km
Permissible current rating in open air
42 A
Permissible current rating when buried
39 A

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
8 (xD)
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Flame retardant
IEC 60332-3 Cat. C
Max. conductor temperature in service
90 °C

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000412-TRDE
  • Certification Date : 1/27/21
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1008
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close