SERVO CABLES ACC. TO DANAHER STANDARD PW+SG
SERVO CABLES ACC. TO DANAHER STANDARD PW+SG
Servo cables with control pair according to DANAHER standard fpr dynamic applications, PUR jacket, shielded, resistant to oils, flame retardant, halogen free
Read moreDescription
Description
Standards
-
ProductUL and CSA approval
Power
Rated voltage:
1000 V
Conductors:
Bare copper
Insulation material:
Polyolefin
Core identification:
Power: Black num. 1+3 + Green/Yellow
Shield:
Tinned copper braid covering > 85%
Binder tape:
Textile no textile
Jacket:
PUR
Colour:
ORANGE RAL 2003 (-A3)
Signal pair
Rated voltage:
600 V
Conductors:
Bare copper
Insulation:
Polyolefin
Core identification:
Black - White
Shield:
Tinned copper wrap covering > 85%
Binder tape :
Textile no textile
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Construction type
-
Conductor material
Bare copper
Insulation
Polyolefin
Insulation colour
Power: Black num 1-3 + Green/Yellow; Signal: Black-White
Lay Up
power cores and control pairs stranded with filler
Taping
Non hygroscopic tape
Shielding
≥85% tinned copper braid coverage
Outer sheath
PUR
Sheath colour
Orange RAL 2003
Halogen free
Yes
Dimensional characteristics
Dimensional characteristics
Nominal outer diameter
- mm
Copper content
- kg/km
Approximate weight
- kg/km
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U
0.6/1 kV
Test voltage
4000 V
Mechanical characteristics
Mechanical characteristics
Maximum acceleration
20 m/s²
Bending cycles
10 Mio.
Speed
220 m/min
Usage characteristics
Usage characteristics
Field of application
Dynamic
Minimum dynamic operating bending radius
- (xD)
Operating temperature, range
-30 ... 80 °C
Storage temperature, range
-40 ... 80 °C
Oil resistance
EN 50363-10-2
Flame retardant
IEC/EN 60332-1-2; FT1; UL 1581 FT1