YHAKXS 6/10KV, 12/20KV, 18/30 KV
YHAKXS 6/10KV, 12/20KV, 18/30 KV
AL/SC/XLPE/SC/SC TAPE/CU WIRES/ low temp. PVC 12/20 (24) KV IEC 60502-2, Flame retardantr
Read moreYHAKXS 1*120/25 12/20KV NEW
Nexans ref. M5A4 000115 - Country ref. M5A4 1*120/25//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 31.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*120/50 12/20KV NEW
Nexans ref. M5A4 000111 - Country ref. M5A4 1*120/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 31.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*150/25 12/20KV NEW
Nexans ref. M5A4 010570 - Country ref. M5A4 1*150/25//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 32.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*150/50 12/20KV NEW
Nexans ref. M5A4 000570 - Country ref. M5A4 1*150/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*150/50 6/10KV
Nexans ref. M3A4 009067
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 29.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*185/25 12/20KV NEW
Nexans ref. M5A4 010571 - Country ref. M5A4 1*185/25//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 34.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*185/50 12/20KV NEW
Nexans ref. M5A4 000049 - Country ref. M5A4 1*185/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 35.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*185/50 12/20KV NEW
Nexans ref. M5A4 010049 - Country ref. M5A4 1*185/50//POL-3L
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 35.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*185/50 6/10KV NEW
Nexans ref. M3A4 001106 - Country ref. M3A4 1*185/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 31.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*240/25 12/20KV NEW
Nexans ref. M5A4 010572 - Country ref. M5A4 1*240/25//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 36.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*240/50 12/20KV NEW
Nexans ref. M5A4 000110 - Country ref. M5A4 1*240/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*240/50 12/20KV NEW
Nexans ref. M5A4 010110 - Country ref. M5A4 1*240/50//POL-3L
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*240/50 6/10KV NEW
Nexans ref. M3A4 001103 - Country ref. M3A4 1*240/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*240/70 12/20KV
Nexans ref. M5A4 000116
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 70 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*240/70 6/10KV NEW
Nexans ref. M3A4 011103 - Country ref. M3A4 1*240/70//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 70 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*240/95 8.7/15KV
Nexans ref. M4A4 000600
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 4.5 mm
- Screen section: 95 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 36.0 mm
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*300/50 12/20KV
Nexans ref. M5A4 011092 - Country ref. M5A4 1*300/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 39.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*300/50 18/30KV
Nexans ref. M6A4 000101
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 8.0 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 44.0 mm
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*500/50 12/20KV NEW
Nexans ref. M5A4 000500 - Country ref. M5A4 1*500/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 500 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 46.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*70/25 12/20KV NEW
Nexans ref. M5A4 000175 - Country ref. M5A4 1*70/25//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 28.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*70/25 18/30KV NEW
Nexans ref. M6A4 011107 - Country ref. M6A4 1*70/25//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 8.0 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 32.0 mm
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*70/25 6/10KV NEW
Nexans ref. M3A4 001107 - Country ref. M3A4 1*70/25//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 24.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 1*800/50 12/20KV
Nexans ref. M5A4 000501 - Country ref. M5A4 1*800/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 800 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.7 mm
- Nominal outer diameter: 56.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 10xD
- Bending factor when laying: 20 (xD)
YHAKXS 3*120/50 6/10KV
Nexans ref. M3A4 001031
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 56.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
YHAKXS 3*185/50 12/20KV NEW
Nexans ref. M5A4 001500 - Country ref. M5A4 3*185/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.3 mm
- Nominal outer diameter: 73.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
YHAKXS 3*185/50 12/20KV NEW
Nexans ref. M5A4 011500 - Country ref. M5A4 3*185/50//POL-3L
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.3 mm
- Nominal outer diameter: 73.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
YHAKXS 3*185/50 6/10KV
Nexans ref. M3A4...000075
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 64.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
YHAKXS 3*240/50 12/20KV NEW
Nexans ref. M5A4 001000 - Country ref. M5A4 3*240/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.5 mm
- Nominal outer diameter: 77.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
YHAKXS 3*240/50 12/20KV NEW
Nexans ref. M5A4 011000 - Country ref. M5A4 3*240/50//POL-3L
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.5 mm
- Nominal outer diameter: 77.0 mm
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
YHAKXS 3*240/50 6/10KV NEW
Nexans ref. M3A4 000071 - Country ref. M3A4 3*240/50//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 68.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
YHAKXS 3*240/70 6/10KV NEW
Nexans ref. M3A4 010500 - Country ref. M3A4 3*240/70//POL-3
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 3.4 mm
- Screen section: 70 mm²
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 67.0 mm
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Cable flexibility: 8xD
- Bending factor when laying: 16 (xD)
Description
Description
Standards
-
ProductIEC 60502-2
-
TestIEC 60332-1-2
Application
Power use outdoor application, even wet.
Suitable for fixed installations at open air, in tube or canals and underground.
Max. Operation temperature: 90°
Max. Short circuit temperature : 250° (Max 5 s)
Construction
AL/SC/XLPE/SC/SC TAPE/CU WIRES/ low temp. PVC
1. Conductor:
Compacted Round conductor class 2
2. Insulation:
Extruded inner semi conductive layer, XLPE insulation and extruded outer semi conductive layer + Semi-conductive tape
3. Metallic screen layer:
Copper wires with open helix copper tape
4. Outer sheath:
Low Temperature PVC, Red or as per customer requirement
5. Marking:
By Inkjet
6. Packing:
Drums can be wooden or steel
TEST AT WORKS / PRÓBY FABRYCZNE
Routine Tests / Badania rutynowe:
• Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag.16.2 / Maks. rezystancja DC żył w temperaturze 20°C zgodnie z IEC 60228 i IEC 60502-2 pkt 16.2
• High voltage test acc. to IEC 60502-2 parag. 16.4 / Próba wysokim napięciem zgodnie z IEC 60502-2 pkt 16.4
• Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.3 / Badanie maksymalnych wyładowań niezupełnych przy 1,73 Uo zgodnie z IEC 60502-2 pkt 16.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided / Firma Liban Cables przeprowadzi te badania dla wszystkich odcinków kabli i dostarczy świadectwa z badań
Sample tests / Badania próbek:
• Check of the build - up and color coding of the cable / Sprawdzenie rozwijania i kolorowych oznaczeń kabla
• Check of dimensions / Sprawdzenie wymiarów
Insulation / Izolacja : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.5.2
Metallic screen / Ekran metaliczny : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.7
Oversheath / Powłoka zewnętrzna : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.5.3
- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10 /-Badanie stopnia usieciowania izolacji z XLPE zgodnie z IEC 60502-2 pkt 17.10
These tests will be carried out on one length of each size during each inspection . / Badania te – podczas każdej kontroli – zostaną przeprowadzone na jednym odcinku dla każdego rozmiaru kabla.
Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables
Type tests / Próby typu
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break ) in accordance with IEC 60502-2. / Charakterystyki mechaniczne materiałów izolacji i powłoki zewnętrznej (wytrzymałość na rozciąganie i wydłużenie przy zerwaniu) zgodnie z IEC 60502-2.
These tests will be carried out on one length of the order / Badania te zostaną przeprowadzone na jednym odcinku z zamówienia
Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables
DRAWING YnHAKXS
Characteristics
Characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania