YHKXS 6/10KV, 12/20KV, 18/30 KV

Products

YHKXS 1*500/50 12/20 KV NEW

Nexans ref. M5N4 001900 - Country ref. M5N4 1*500/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 500 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 47.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHKXS 1*630/50 12/20 KV

Nexans ref. M5N4 010807

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.6 mm
  • Nominal outer diameter: 51.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHKXS 1*630/50 12/20 KV NEW

Nexans ref. M6N4 001155 - Country ref. M6N4 1*630/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 47.1 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHKXS 1*630/95 6/10 KV

Nexans ref. M3N4 001631

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 48.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHKXS 1*800/50 12/20 KV

Nexans ref. M5N4 010808

  • Packaging: Cut to length (m)
  • Conductor cross-section: 800 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 59.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

Description

Description

Standards

  • Product
    IEC 60502-2
  • Test
    IEC 60332-1-2

Application

Power use outdoor application, even wet.

Suitable for fixed installations at open air, in tube or canals and underground.

Max. Operation temperature: 90°

Max. Short circuit temperature : 250° (Max 5 s)

Construction

CU/SC/XLPE/SC/SC TAPE/CU WIRES/ low temp. PVC

1. Conductor:

Compacted Round conductor class 2

2. Insulation:

Extruded inner semi conductive layer, XLPE insulation and  extruded outer semi conductive layer + Semi-conductive tape

3. Metallic screen layer:

Copper wires with open helix copper tape

4. Outer sheath:

Low Temperature PVC, Red or as per customer requirement

5. Marking:

By Inkjet

6. Packing:

Drums can be wooden or steel

TEST AT WORKS according to IEC 60502-2

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided                                                                 

                                                                       

Sample tests

 -          Check of the build - up and color coding of the cable                                                      

 -          Check of dimensions                                                    

            Insulation          :           according to IEC 60502-2                       Parag.  17.5.2

            Metallic screen  :           according to IEC 60502-2                       Parag.  17.7

            Oversheath       :           according to IEC 60502-2                       Parag.  17.5.3

- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10

                                                                       

These tests will be carried out on one length of each size during each inspection .                                                                       

Tests certificates will be provided by Liban Cables                                                                      

                                                                       

Type tests

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-2.                                                                     

These tests will be carried out on one length of the order.

Tests certificates will be provided by Liban Cables

DRAWING YnHKXS

Characteristics

Characteristics

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

U.V resistance
Yes
Laying depth, center of system
800 mm
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close