FLAMEX® EN 50264-3-1 MM 3600V
FLAMEX® EN 50264-3-1 MM 3600V
FLAMEX
SHEATHED SINGLE CORE POWER CABLES
FLAMEX® EN 50264-3-1 3600V MM power cables are used for fixed and protected installations. This product range is recommended for narrow spaces where an optimal bending radius is required. FLAMEX® cables are designed to withstand tough working conditions (oil, ozone, temperature variation, etc.). 120°C conductor temperature is allowed for a 20,000 hours cumulative working time.
FLAMEX EN 50264-3-1 3600V 2.5 MM
Nexans ref. 79462430
- Packaging: Drum (1000m)
- Conductor cross-section: 2.5 mm²
- Minimum outer diameter: 8.9 mm
- Maximum outer diameter: 9.3 mm
- Approximate weight: 115 kg/km
FLAMEX EN 50264-3-1 3600V 4 MM
Nexans ref. 79462530
- Packaging: Drum (1000m)
- Conductor cross-section: 4 mm²
- Minimum outer diameter: 9.6 mm
- Maximum outer diameter: 10.0 mm
- Approximate weight: 130 kg/km
FLAMEX EN 50264-3-1 3600V 6 MM
Nexans ref. 79462630
- Packaging: Drum (1000m)
- Conductor cross-section: 6 mm²
- Minimum outer diameter: 10.3 mm
- Maximum outer diameter: 10.7 mm
- Approximate weight: 160 kg/km
FLAMEX EN 50264-3-1 3600V 10 MM
Nexans ref. 79462730
- Packaging: Drum (1000m)
- Conductor cross-section: 10 mm²
- Minimum outer diameter: 11.1 mm
- Maximum outer diameter: 11.7 mm
- Approximate weight: 210 kg/km
FLAMEX EN 50264-3-1 3600V 16 MM
Nexans ref. 79462830
- Packaging: Drum (1000m)
- Conductor cross-section: 16 mm²
- Minimum outer diameter: 12.9 mm
- Maximum outer diameter: 13.5 mm
- Approximate weight: 300 kg/km
FLAMEX EN 50264-3-1 3600V 25 MM
Nexans ref. 79462930
- Packaging: Drum (1000m)
- Conductor cross-section: 25 mm²
- Minimum outer diameter: 14.7 mm
- Maximum outer diameter: 15.3 mm
- Approximate weight: 400 kg/km
FLAMEX EN 50264-3-1 3600V 35 MM
Nexans ref. 79463030
- Packaging: Drum (1000m)
- Conductor cross-section: 35 mm²
- Minimum outer diameter: 16.0 mm
- Maximum outer diameter: 16.6 mm
- Approximate weight: 520 kg/km
FLAMEX EN 50264-3-1 3600V 50 MM
Nexans ref. 79463130
- Packaging: Drum (1000m)
- Conductor cross-section: 50 mm²
- Minimum outer diameter: 17.5 mm
- Maximum outer diameter: 18.1 mm
- Approximate weight: 650 kg/km
FLAMEX EN 50264-3-1 3600V 70 MM
Nexans ref. 79463230
- Packaging: Drum (1000m)
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 19.2 mm
- Maximum outer diameter: 19.8 mm
- Approximate weight: 880 kg/km
FLAMEX EN 50264-3-1 3600V 95 MM
Nexans ref. 79463330
- Packaging: Drum (1000m)
- Conductor cross-section: 95 mm²
- Minimum outer diameter: 21.5 mm
- Maximum outer diameter: 22.1 mm
- Approximate weight: 1150 kg/km
FLAMEX EN 50264-3-1 3600V 120 MM
Nexans ref. 79463430
- Packaging: Drum (1000m)
- Conductor cross-section: 120 mm²
- Minimum outer diameter: 23.5 mm
- Maximum outer diameter: 24.1 mm
- Approximate weight: 1400 kg/km
FLAMEX EN 50264-3-1 3600V 150 MM
Nexans ref. 79463530
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Minimum outer diameter: 24.7 mm
- Maximum outer diameter: 25.5 mm
- Approximate weight: 1700 kg/km
FLAMEX EN 50264-3-1 3600V 185 MM
Nexans ref. 79463630
- Packaging: Drum (1000m)
- Conductor cross-section: 185 mm²
- Minimum outer diameter: 26.9 mm
- Maximum outer diameter: 27.7 mm
- Approximate weight: 2050 kg/km
FLAMEX EN 50264-3-1 3600V 240 MM
Nexans ref. 79463730
- Packaging: Drum (1000m)
- Conductor cross-section: 240 mm²
- Minimum outer diameter: 29.9 mm
- Maximum outer diameter: 30.7 mm
- Approximate weight: 2600 kg/km
Description
Description
Standards
-
ProductEN 50264-3-1; EN 45545 - HL3; IEC 60228
DESIGN
1. Conductor
Flexible stranded tinned copper class 5 acc. to IEC 60228
Conductor screen
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-1
Colour: grey
3. Sheath
Cross-linked compound type EM 104 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Example of marking: FLAMEX EN 50264-3-1 3600V (mm²) MM NSHXAFOE 3.6/6kV I LYNXEO I WW-YYYY
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 4 x outer cable diameter (5 x D if D>10mm)
- For installation and occasional movements: 10 x outer cable diameter
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania